Premier Safety is an “essential business” for customers, including government agencies, hospitals, first responders, food producers, utilities and pharmaceutical manufacturers. Our locations remain open. Inventory positions remain strong in categories not directly impacted by the pandemic. We at Premier Safety are committed to your health and safety. More COVID-19 Details >

TSI Model 8710 DP-CALC™ Micromanometer-RENTAL

TSI Inc.

Model 8710 DP-CALC Micromanometer is a comprehensive measurement solution for industrial hygienists, certification personnel and HVAC professionals who measure pressure, temperature, velocity and flow. This innovative instrument features a velocity matrix, auto zero, full datalogging and low-flow accuracy for fast, reliable measurements.

Rental Includes: Model 8710 Micromanometer, 16-Point Velocity Matrix, Telescopic Handle, Carrying Case, 18" (46 cm) Pitot Probe, 2 Static Pressure Probes, (2) 8' Neoprene Tubing, Instruction Manual, LogDat Software, Serial Interface Cable, Neck Strap, Internal Battery Charger, 4 AA NiMH Rechargeable Batteries, AC Adapter, NIST Traceable Calibration.

Differential Pressure

Range:

  • ±15 in. wc (3735 Pa); 150 in. wc maximum safe operating pressure
  • Accuracy: 2% of reading; ±0.001 in. wc (0.025 mm wc) from 0.050 to 15 in. wc
  • Resolution: 0.00001 in. wc (0.00025 mm wc)
  • Absolute Pressure: Range 15 to 40 in. Hg (356 to 1016 mm Hg)
  • Accuracy: 2% of reading
  • Resolution: 0.01 in. Hg (1 mm Hg)
  • Air Velocity*

Range:

  • 25 to 8,000 ft/min (0.13 to 41 m/s) Pitot Probe
  • 25 to 5,000 ft/min (0.13 to 25 m/s) Air Flow Probe
  • 25 to 2,500 ft/min (0.13 to 13 m/s) Velocity Matrix
  • Accuracy: 3% of reading; ±7 ft/min (0.04 m/s)** All Probes
  • Temperature Probe*

Range:

  • -40 to 250°F (-40 to 121°C) probe dependent
  • Resolution: 0.1 °F (0.1 °C)
  • Relative Humidity Probe*

Range:

  • 0 to 95% RH
  • Accuracy: 3% RH
  • Resolution: 0.1% RH
  • Averaging Capability: Up to 1,000 values each of measured parameter
  • Sampling Interval: Continuous or user selectable (10 to 600 s)
  • Response Time: 2 to 8 s
  • Operating Range: 40 to 140°F (4.4 to 60°C)
  • Power: 4 AA-size rechargeable NiMH (included) or alkaline batteries, AC adaptor
  • Battery Life: 12 hr
  • These specifications apply when the applicable accessory probes are used with the Model 8710 Micromanometer.
  • At >50 ft/min

Style: Daily
Instrumentation Types: Anemometer
UOM: EA

Model 8710 DP-CALC™ micromanometer

Primary Image

TSI Model 8710 DP-CALC™ Micromanometer-RENTAL

Manufacturer: TSI Inc.
Mfr# 495-1001

$80.00

UOM: EA
Technical Details
Style Daily
Instrumentation Types Anemometer
Style: Weekly
Instrumentation Types: Anemometer
UOM: EA

Model 8710 DP-CALC™ micromanometer

Primary Image

TSI Model 8710 DP-CALC™ Micromanometer-RENTAL

Manufacturer: TSI Inc.
Mfr# 495-1001

$240.00

UOM: EA
Technical Details
Style Weekly
Instrumentation Types Anemometer
Style: Monthly
Instrumentation Types: Anemometer
UOM: EA

Model 8710 DP-CALC™ micromanometer

Primary Image

TSI Model 8710 DP-CALC™ Micromanometer-RENTAL

Manufacturer: TSI Inc.
Mfr# 495-1001

$720.00

UOM: EA
Technical Details
Style Monthly
Instrumentation Types Anemometer