Image coming soon

BW Technologies ToxiPro™ 54-47-03 Replacement Sensor, Sulfur Dioxide, 0 to 100 ppm

$652.40
(No reviews yet) Write a Review
SKU:
54-47-03
Prelude ID:
BIO54-47-03
Stocking Status:
Non Stock
Hazardous:
N
UOM:
EA
Adding to cart… The item has been added
BW Technologies Replacement Sensor, ToxiPro™, Detects: Sulfur Dioxide, 0 to 100 ppm Sensor, 0.1 ppm Resolution, For Use With: ToxiPro™ Single-Gas Detectors
  • Operates with or without a controller
  • Direct digital readout with OLED cold temperature display
  • 4 to 20 mA and digital Modbus outputs standard
  • 2 fully programmable alarm relays and fail relay
  • Non-intrusive calibration via magnetic wand
  • Explosion proof construction
  • Patented water repellent sensor cover
  • User friendly setup, push buttons and OLED menus
  • Long life sensors (2+ years typical)
  • Item Name - Replacement Sensor
  • Series - ToxiPro™
  • Suitable For Use With - ToxiPro™ Single-Gas Detectors
  • Resolution - 0.1
  • Detects - Sulfur Dioxide
  • Sensor Range - 0 to 100
  • Marketing Description - The RKI M2A™ is a state-of-the-art transmitter that can operate as an independent, stand alone monitor or as part of an integrated system. The M2A™ connects with an analog or digital signal to virtually any controller, PLC, or DCS. Setup procedures are simplified with user friendly push buttons and OLED menus. It utilizes a magnetic wand technique for performing non-intrusive calibration. The M2A™ provides an automatic zero drift correction feature, which results in more stable readings and reduces the need for adjustments due to sensor aging. The housing of the M2A™ does not need to be opened for zeroing or calibration, making it unnecessary to declassify the area for routine maintenance. It is designed so that a complete field calibration can be performed by one person. Sensor construction is rated Class I, Div. 1 Groups B, C, D for flammables, CO, H2S, O2, and CO2, and Class I, Div. 2 for all other toxics. The transmitter provides a 4 to 20 mA output in addition to a Modbus digital output. It also has two levels of alarms with relays, plus a fail alarm with relay. A digital display of the gas concentration, as well as alarm and status lights, can be viewed through the front window. The toxic sensors are electrochemical type plug-in sensors, which provide high specificity, fast response, and long life. The plug-in design allows quick replacement in the field with no tools required. Toxic sensors are designed for use in Class I, Div. 2 hazardous locations. Sensors available for NH3, SO2, PH3, AsH3, and HCN. The M2A™ represents the latest leading edge technology in sensor/transmitters today.